Troubleshooting
310 3ware SAS/SATA RAID Software User Guide, Version 9.5.1
8041 Enclosure voltage over
Event Type
Error.
Cause
Applies only to the 9690SA controller.
The enclosure power supply voltage is higher than the normal range.
Action
This error is rare. If you see it you may need a UPS or voltage regulator to
stay within the recommended voltage range.
8042 Enclosure voltage under
Event Type
Error.
Cause
Applies only to the 9690SA controller.
The enclosure power supply voltage is lower than the normal range. This can
be due to a failing power supply or an unreliable power source.
Action
If due to a failing power supply, replace it as soon as possible.
It is recommended to use an uninterruptible power supply (UPS) to protect
against power failures.
8043 Enclosure voltage unknown
Event Type
Warning.
Cause
Applies only to the 9690SA controller.
The enclosure is not reporting voltage data. This can be due to a failing power
supply.