Error and Notification Messages
www.3ware.com 233
Action
Allow the rebuild to complete. This will return the unit to its normal
redundant state.
See Also
“Scheduling Background Tasks” on page 156.
“Rebuilding Units” on page 150.
“Background Task Prioritization” on page 156.
000C Initialize started
Event Type
Information
Cause
The 3ware RAID controller started an initialization. This is always a
“synching” background initialization and does not erase user data.
Initialization either occurs at unit creation time for larger RAID 5, 6, or 50
units or later during the initial verification of redundant units.
Action
Allow the initialization to complete. This will return the unit to its normal
redundant state.
See Also
For more information, see “About Initialization” on page 143
000E Initialize failed
Event Type
Error
Cause
The 3ware RAID controller was unable to complete the initialization. This
error can be caused by unrecoverable drive errors.
If this unit was a redundant unit, and the initialization failed because of a
problem on a particular disk drive, then the unit will be degraded.
Action
If the unit was degraded, then rebuild the unit. This may necessitate replacing
the drive.